User Manual ESY-1 / rev. 9 15.01.2008 www.selproweb.com
2
Contents:
Safety Warnings .................................................................................................................................................... Errore. Il segnalibro non è definito.
Precautions .................................................................................................................................................................................................................. 1
Contents ...................................................................................................................................................................................................................... 2
1. ..
EC DIRECTIVES & TECHNICAL STANDARDS ...................................................................................................................................... 3
2. .. Mechanical Dimensions ESY-1 ...................................................................................................................................................................... 3
3. .. OPERATING MODES AND APPLICATIONS ............................................................................................................................................ 4
4. .. TECHNICAL CHARACTERISTICS ESY-1 ................................................................................................................................................ 5
5. .. ELECTRICAL CONNECTIONS .............................................................................................................. Errore. Il segnalibro non è definito.
5.1. Power Supply Connection (Terminal Block M1) ........................................................................................................................................... 7
6. .. SIGNAL CONNECTIONS for the 4 CONFIGURATIONS (ALL-in-ONE) ............................................................................................... 8
6.1. OM CONFIGURATION (STANDARD SELPRO) ....................................................................................................................................... 8
6.2. OX Configuration (on request) ....................................................................................................................................................................... 8
6.3. OV Configuration (on request) ....................................................................................................................................................................... 9
6.4. OB Configuration (on request) ....................................................................................................................................................................... 9
7. .. Electrical connection for Slave Module/s ..................................................................................................................................................... 10
7.1. Connection of SLAVE modules, SV series (0-10Vdc power units) ............................................................................................................. 10
7.2. Connecting ESY-1 to SLAVE-SV / 0-10 Vdc modules (Three-/Single-phase connection) ........................................................................ 10
7.3. Connection of SLAVE modules, SP series (PWM power units) ................................................................................................................. 11
7.4. Connecting SLAVE-SP modules – Power supply in phase with the Master unit (network synchronization) ......................................... 11
8. .. ESY-1: CONTROL & POWER CARD IN DETAIL, ALL-in-ONE version ............................................................................................ 12
8.1. ESY-1: CONTROL & POWER CARD IN DETAIL, SLAVE-ONE versions........................................................................................... 12
8.2. LED signals .................................................................................................................................................................................................... 13
8.3. Configuration and selection JUMPERS ....................................................................................................................................................... 13
9. .. Set-up of operating LIMITS and PARAMETERS ...................................................................................................................................... 14
9.1. Available regulations in the standard ESY-1 version (ALL-in-ONE) ........................................................................................................ 14
9.2. How to set up the operating limits for the ALL-in-ONE version) .............................................................................................................. 14
9.3. How to set up the operating limits for SLAVE-ONE modules (only SLAVE-SV version) ....................................................................... 15
9.4. Table showing the scale of values for setting up the ESY-1 regulation VAC Limits................................................................................. 15
9.5. Tables for the Set-Point selection: ................................................................................................................................................................ 16
9.5.1. Set-Point values, range 0-15 bar (Transducer 4-20 mA)........................................................................................................................... 16
9.5.2. Set-Point values, range 0-15 bar (Transducer 4-20 mA)........................................................................................................................... 16
9.5.3. Set Point values, range 0-25 bar (Transducer 4-20 mA) ............................................................................................................................ 17
9.5.4. Set Point values, range 0-30 bar (Transducer 4-20 mA) ............................................................................................................................ 17
9.5.5. Set-Point values, range 0-45 bar (Transducer 4-20 mA).......................................................................................................................... 18
9.5.6. Set Point values, range 0-30 bar (Transducer 0,5-4,5 Vdc) ....................................................................................................................... 18
9.5.7. Set-Point values, range 10°C to 60°C (NTC probe 10kohm@25°C) ......................................................................................................... 19
9.6. Regulation with Double SET-Point (optional) ............................................................................................................................................ 19
10. Function diagrams & Operating parameters in MASTER & SLAVE modes ........................................................................................ 20
10.1. ESY-1 MASTER mode ................................................................................................................................................................................. 20
10.2. ESY-1 SLAVE mode .................................................................................................................................................................................... 20
11. ACCESSORIES ............................................................................................................................................................................................ 21
11.1. Manual Remote Control Units.................................................................................................................. Errore. Il segnalibro non è definito.
11.2. Pressure Transducer for 4-20 mA & 0-5 V ................................................................................................................................................. 22
11.3 Temperature Probe NTC (10 kohm@25°C) ............................................................................................ Errore. Il segnalibro non è definito.
11.4 RGF-MEI(4) / UNIVERSAL input Expansion Module .......................................................................... Errore. Il segnalibro non è definito.
PRODUCT end of life
The device must be disposed of separately, according to the local authority
advice.