On New Concrete
Ensure that at least 40” of wire extends out of the conduit.
Insert the anchor plate into the concrete immediately after pouring the concrete.
It is recommended to vibrate the concrete to eliminate any air bubbles.
Anchor plate surface should be in level with the ground.
On Existing Concrete
Ensure that at least 40” of wire extends out of the conduit.
Mark anchoring points with the help of anchor plate template.
Drill 4 holes into the concrete, each minimum 2.2” deep.
Put anchor bolts provided by SemaConnect, ensuring that bolts extend out.
Place anchor plate on top of stud anchors.
Installation Manuals Series 6 EV Charging Station - 1
Copyright ©2021 SemaConnect, Inc. All rights reserved. Page 15 of 25