Motor Head Unit InstallationMotor Head Unit Installation
LISH
E
N
G
22
Tightening the motor unit on a door with side plates
(KRAZI-DOOR, etc..)
For KRAZI DOOR (and other similar doors) it is
necessary to fabricate a steel baseplate and use
it in conjunction with the supplied u-bolt. This
configuration is the only acceptable one - not
doing this exactly as shown will lead to product
failure which is not covered by warranty!
Using steel bar, as indicated in "Required Tools and Equipment",
fabricate a steel baseplate with the following dimensions:
70mm
97mm
25mm
48.5mm
12.5mm
DIA TO SUIT TEK SCREW USED
DIA = 10mm
PLATE THICKNESS = 5~7mm
Notes:
Ensure all holes are drilled correctly- if they are too small it will be difficult to install
the u-bolt assembly with this baseplate.
Use of material thinner than 5mm is not recommended as it will distort and fatigue
due to the forces the door exerts on this part.