Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, injury or death. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing this
equipment.
WARNING!
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.
FOR YOUR SAFETY
www.servware.com
800•768•5953
Save These Instructions!
Parts & Service Manuals Available at:
IMPORTANT INFORMATION
ABOUT YOUR UNIT ENCLOSED.
PLEASE READ BEFORE USE!
SS -SGF - 40L
SS - SGF -4 0N
SS -SGF -50L
SS - SGF - 50 N
SS - SGF -70L
SS- S GF-70 N
Instruction, Service, Installation, and Care Manual
Please read this manual completely before attempting to install or operate this
equipment. Notify carrier of damage! Inspect all components immediately.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
FOR QUESTIONS, CONTACT THE
SERVICE DEPARTMENT AT:
service@servware.com or
800•768•5953
Fryer Gas Cabinets :
40 - 50 - 70
Question and Answer IconNeed help?

Do you have a question about the SERV-WARE SELECT SS-SGF-40L and is the answer not in the manual?

Summary

IMPORTANT SAFETY INSTRUCTIONS

RECEIVING AND INSPECTING THE EQUIPMENT

02. EQUIPMENT INSTALLATION

2.4 Gas Installation

Covers the requirements for gas line sizing and installation to ensure peak appliance performance.

2.4.1 Gas Supply to the Appliance

Specifies correct gas supply pressure ranges for natural and propane gas for optimal operation.

2.5 Gas Leak Check

Details the procedure for checking gas supply lines for leaks using a soapy water solution.

2.9 Turning on the Equipment - Product Ignition

Provides detailed steps for safely lighting the pilot and main burners of the gas fryer.

03. CLEANING AND MAINTENANCE

3.1.1 Cleaning the Inside of the Equipment

Provides step-by-step instructions for draining oil, cleaning the tank, and rinsing components.

3.2.1 Preventive Maintenance

Recommends semi-annual servicing by a qualified technician for peak operational efficiency.

04. KNOWING THE EQUIPMENT

05. TECHNICAL SPECIFICATIONS

LIMITED ORIGINAL COMMERCIAL EQUIPMENT WARRANTY

Overview

The Serv-Ware Fryer Gas Cabinets (models 40, 50, and 70) are commercial-grade gas fryers designed for cafeteria, restaurant, and general kitchen use. These units are built for durability, performance, and efficiency in food preparation, specifically for frying with oil or vegetable fat.

Function Description:

The primary function of the Serv-Ware Fryer Gas Cabinets is to provide a reliable and efficient means of deep-frying food. The design focuses on achieving a uniform cooking process by utilizing a tank that acts as an intermediary between the heat source (fire) and the food. This calorific capacity ensures optimal flavor in the fried food. The fryers are equipped with a gas distribution and flare assembly, thoroughly tested to ensure safety and efficiency of the cast iron burners. A thermopile system is integrated for safety, ensuring the pilot flame remains active and detecting flame presence to prevent gas flow to a burner if no flame is detected. The pilot flame is designed to stay lit throughout the workday after initial ignition, minimizing gas consumption.

Important Technical Specifications:

The fryers are available in three capacities:

  • SS-SGF-40L/N: 40 lb (16 l) capacity
  • SS-SGF-50L/N: 50 lb (20 l) capacity
  • SS-SGF-70L/N: 75 lb (30 l) capacity

Key dimensions and weights vary by model:

  • SS-SGF-40L: Width (W) 16", Depth (D) 31 7/32", Height (H) 48 27/64", Fw 15 11/32", Weight 110 lb.
  • SS-SGF-50L: Width (W) 16", Depth (D) 31 7/32", Height (H) 48 27/64", Fw 15 11/32", Weight 143 lb.
  • SS-SGF-70L: Width (W) 20", Depth (D) 33 45/64", Height (H) 48 27/64", Fw 18 45/64", Weight 157 lb.

Shipping crate dimensions and weights are also provided for each model.

Gas supply specifications:

  • Gas Connection: 3/4" NPT external thread intake-tube. Gas supply line should be the same size or larger.
  • Supply Pressure:
    • Natural Gas: 7.0" W.C. (17.4 mbars, 1.74 kPa) to 10.0" W.C. (24.9 mbars, 2.49 kPa)
    • Propane Gas: 11.0" W.C. (27.4 mbars, 2.74 kPa) to 13.0" W.C. (32.4 mbars, 3.25 kPa)
  • Manifold Pressure: 10" W.C. for Propane Gas, 4" W.C. for Natural Gas.
  • BTU/h Input:
    • SS-SGF-40L: 90,000 BTU/h (Natural Gas & Propane Gas)
    • SS-SGF-50L: 120,000 BTU/h (Natural Gas & Propane Gas)
    • SS-SGF-70L: 150,000 BTU/h (Natural Gas & Propane Gas)
  • Burners: SS-SGF-40L has 3 burners, SS-SGF-50L has 4 burners, and SS-SGF-70L has 5 burners.
  • Thermostat: Millivolt Thermostat, 200 °F - 400 °F (93.3 °C – 204.4°C).
  • Safety Features: High-Temperature safety limit switch, Thermo-Safety pilot with built-in regulator, Separate Manual gas shut-offs for front servicing.

Usage Features:

  • Installation: Requires installation in accordance with local codes (National Fuel Gas Code ANSI Z223.1 in the US, CAN/CGA-B149.1 or B149.2 in Canada). Installation must be performed by qualified and authorized persons. A gas pressure regulator (supplied with the equipment) must be installed.
  • Clearances: Requires 10" (254 mm) rear and 6" (152.4 mm) side clearance from combustible surfaces. No clearance is required from non-combustible surfaces.
  • Foot Leveling: Equipped with four adjustable legs for stable and level placement on the work surface.
  • First Time Use: Before operation, all protective PVC film, plastics, and straps must be removed. A preliminary cleaning with neutral soap and water is recommended. The tank should be filled with vegetable oil or shortening to the indicated level before ignition.
  • Ignition: Involves opening the manual gas supply valve, turning the gas valve knob to "pilot mode" and squeezing for 30 seconds to release gas, lighting the pilot with a wick, and then turning the knob to "ON" and setting the desired temperature.
  • Drainage: Features a 1 1/4" Full port drain valve for fast draining, facilitated by an accessory tube for oil removal.
  • Construction: Stainless steel tank for durability and high production output, stainless steel front, door, and sides for the cabinet. Heavy-duty cast iron burners and heavy gauge metal tubes. Heavy gauge deflector system for quicker recovery time.
  • Mobility: 6" (152 mm) swivel castors can be purchased separately. If equipped with casters, appliances must be installed with quick disconnect connectors complying with ANSI Z21.69.CSA 6.16 and ANSI Z21.41.CSA 6.9.

Maintenance Features:

  • Cleaning:
    • Inside: Recommended daily cleaning. After oil cools, drain using the accessory tube. Rinse with hot water to remove debris, then fill with water and neutral detergent, boil for 15 minutes, and scrub with a plastic bristle brush. Drain, rinse with clean water, use vinegar (250ml to 20 liters of water) to neutralize detergent, and rinse again with clean water. Always ensure oil is at room temperature before cleaning to prevent burns.
    • Outside: Allow equipment to cool. Clean daily dirt with a mild detergent or soap solution applied with a damp cloth, then wash and dry thoroughly. Avoid sharp or abrasive materials, strong/abrasive cleaners, and direct water jets to prevent damage and corrosion.
  • Preventive Maintenance: To ensure maximum efficiency and reduce downtime, annual or semi-annual service by a qualified technician is recommended. This includes:
    • Examining air inlets (rear and bottom) and air vents (hood) at least twice a year.
    • Cleaning and adjusting burners, regulators, etc., twice a year.
    • Checking and calibrating the gas supply system pressure at least once a year.
  • Oil Replacement: Oil should be replaced when it shows foam, smoke, sharp color, or odors.
  • Parts & Service: Parts and service manuals are available online at www.servware.com. For repairs, contact an authorized service technician and request original replacement parts. Unauthorized alterations or tampering are dangerous and void all warranties.
  • Gas Leak Check: Before operation, all gas supply line gaskets must be checked for leaks using a sudsy soap and water solution. Active bubbling indicates a leak, requiring immediate shutdown of the manual gas valve and calling a certified technician.

SERV-WARE SELECT SS-SGF-40L Specifications

General IconGeneral
BrandSERV-WARE
ModelSELECT SS-SGF-40L
CategoryCommercial Food Equipment
LanguageEnglish