Drive Technology \ Drive Automation \ System Integration \ Services
Operating Instructions
Safety-Related BST Brake Module
for Control Cabinet Installation
Edition 10/2011 19357214 / EN
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive BST Series and is the answer not in the manual?

SEW-Eurodrive BST Series Specifications

General IconGeneral
SeriesBST
CategoryControl Unit
Protection classIP20
Communication interfacesPROFIBUS, CANopen
Ambient temperature range0°C to +40°C
Relative humidity5 ... 95 %, non-condensing

Summary

Safety Notes

Integrated Safety Technology

Safety Function

Describes the SBC function for safely de-energizing the brake via control voltage disconnection.

Safety-Relevant Conditions

Permitted Unit Combinations

Lists BST unit types and SEW disk brakes permitted for safety-related applications.

Requirements on the Installation

Specifies requirements for power and control lines, cable lengths, and cabinet protection (IP54).

Requirements on External Safety Controller

Details requirements for safety relays and controllers, including safety class and wiring.

Requirements on Startup

Outlines requirements for documenting and demonstrating safety functions during startup and checks.

Requirements on the Operation

Specifies requirements for operation within data sheet limits and regular safety function checks.

Installation

Mechanical Installation

Details mounting the BST module onto a support rail in a control cabinet.

Electrical Installation

Covers cable requirements (supply, functional, safety-related) and safe disconnection methods (single/double-pole).

Startup

Applications

Disconnection of Single Drives via Inverter (Example MOVIDRIVE® B)

Shows wiring diagrams for SBC with STO using MOVIDRIVE® B inverter.

Disconnection of Single Drives via Inverter and DFS11B/21B Fieldbus Interface

Illustrates wiring for SBC with STO using MOVIDRIVE® B and DFS11B/21B fieldbus.

Disconnection of Group Drives

Depicts wiring diagrams for SBC with STO for disconnecting group drives.

Technical Data

Safety Characteristics of BST Brake Modules

Details safety characteristics like PL d, Category 3, and PFH value according to EN ISO 13849-1.