EasyManua.ls Logo

SEW-Eurodrive MOVITRAC LT Series

SEW-Eurodrive MOVITRAC LT Series
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Drive Electronics \ Drive Automation \ System Integration \ Services
Operating Instructions
MOVITRAC
®
LT
Option Cards
Edition 09/2009 16822013 / EN
Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive MOVITRAC LT Series and is the answer not in the manual?

SEW-Eurodrive MOVITRAC LT Series Specifications

General IconGeneral
Product TypeFrequency Inverter
SeriesMOVITRAC LT
Protection ClassIP20
Control MethodV/f control
Output Voltage0 to input voltage
Ambient Temperature-10 °C to +50 °C (derating may apply above 40°C)
Relative Humidity≤95% (non-condensing)
AltitudeUp to 1000 m above sea level (derating may apply above 1000m)

Summary

Important Notes

How to Use Operating Instructions

Guidance on utilizing the operational documentation effectively.

Structure of Safety Notes

Explanation of how safety information is organized within the document.

Right to Claim Under Limited Warranty

Conditions for warranty claims and adherence to instructions.

Exclusion of Liability

Disclaimer regarding SEW-EURODRIVE's liability for improper use.

Copyright Notice

Legal notice regarding intellectual property rights and usage restrictions.

Waste Disposal

Guidelines for environmentally sound disposal of product components.

Safety Notes

Preliminary Information

Introduction to fundamental safety precautions for frequency inverters.

General Safety Directives

Broad safety directives and warnings for operation and maintenance.

Target Personnel

Identification of qualified personnel for mechanical and electrical work.

Designated Use and Standards

Specifies approved applications and standards for frequency inverters.

Transport Precautions

Instructions for inspecting and handling shipments to prevent damage.

Installation and Assembly

Guidelines for safe and correct installation and assembly of units.

Electrical Connection Safety

Procedures and regulations for safe electrical connections.

Safe Disconnection Procedures

Requirements for ensuring safe power disconnection of units and circuits.

Startup and Operation Safety

Precautions for safe startup and initial operation of the equipment.

Operation and Servicing Safety

Safety measures during ongoing operation and maintenance activities.

Mechanical Installation

Preliminary Work

Steps to take before installing the option card.

Installation Procedure

Detailed steps for physically installing the option card.

Second Analog Input

Supported Unit Types

Lists the MOVITRAC® models compatible with this option card.

Overview of Functionality

Describes the purpose and typical applications of the second analog input.

Technical Data

Provides specifications for the analog input functionality.

Electrical Interface Details

Details the terminal connections and signal assignments for the option card.

Operation and Configuration

Explains how to configure and use the second analog input.

Second Relay Output

Supported Unit Types

Lists the MOVITRAC® models compatible with the second relay output.

Overview of Functionality

Describes the function and typical applications of the second relay output.

Electrical Interface Details

Details the terminal connections and signal assignments for the relay output.

Technical Data

Provides specifications for the second relay output.

Operation and Programming

Explains how to program and use the second relay output.

Third Relay Output

Supported Unit Types

Lists the MOVITRAC® models compatible with the third relay output.

Overview of Functionality

Describes the function and typical applications of the third relay output.

Electrical Interface Details

Details the terminal connections and signal assignments for the third relay output.

Technical Data

Provides specifications for the third relay output.

Operation and Programming

Explains how to program and use the third relay output.

Two Indicator Relay

Supported Unit Types

Lists compatible MOVITRAC® models for the two indicator relay.

Overview of Functionality

Explains the purpose of the two indicator relay option.

Electrical Interface Details

Details the terminal connections for the two indicator relay.

Technical Data

Provides specifications for the two indicator relay.

Operation in MOVITRAC LTE-B

How to configure the two indicator relay for LTE-B models.

Operation in MOVITRAC LTP

How to configure the two indicator relay for LTP models.

PI Controller

Supported Unit Types

Lists compatible MOVITRAC® models for the PI controller.

Overview of Functionality

Explains the PI controller's function and benefits for feedback control.

Electrical Interface Details

Details the terminal connections and signal assignments for the PI controller.

Technical Data

Provides specifications for the PI controller.

Operation and Setup

How to set up and operate the PI controller card.

Converter Card

Supported Unit Types

Lists compatible MOVITRAC® models for the converter card.

Overview of Functionality

Explains the function of the converter card for digital inputs.

Electrical Interface Details

Details the terminal connections and signal assignments for the converter card.

Technical Data

Provides specifications for the converter card.

Operation Modes

How to configure the converter card for different input types.

Local Switchboard

Supported Unit Types

Lists compatible MOVITRAC® models for the local switchboard.

Overview of Functionality

Explains the function of the local switchboard as an auxiliary control.

Electrical Interface Details

Details the terminal connections for the local switchboard.

Technical Data

Provides specifications for the local switchboard.

Related product manuals