Operating Instructions – Explosion-Proof AC Motors DR63/eDR63, DVE250/280
19
4
Motor installation notes
Mechanical Installation
Make sure that there is sufficient clearance around the motor/brakemotor to provide
for adequate cooling, and that the motor does not draw in warm air from other units.
Observe the following minimum clearance:
Balance components for subsequent mounting on the shaft with a half key (motor
shafts are balanced with a half key).
If you have used the hand lever of the self-reengaging manual brake release during
startup, you must remove the lever again for regular operation. A bracket is provided
for storing the lever on the outside of the motor housing.
4.3.1 Installation in damp locations or outdoors
Use suitable cable glands for the incoming cable (use reducing adapters if neces-
sary) according to the installation instructions.
If possible, arrange the terminal box in such a way that the cable entries are pointing
downwards.
Seal the cable entry properly.
Thoroughly clean the sealing surfaces of the terminal box and the terminal box cover
prior to reassembly. Replace any brittle seals!
If required, touch up the corrosion protection (especially at the eyebolts).
Check the degree of protection.
Protect the shaft against corrosion using a suitable anti-corrosion agent.
Motor type h in mm
eDR63, DR63 15
DVE250
40
DVE280
h
INFORMATION
If using belt pulleys:
Only use belts that do not build up an electrostatic charge.
Do not exceed the maximum permitted overhung load; for motors without gear
units, see chapter "Overhung loads (page 51)".
Motors in vertical mounting position (e.g. M4/V1) are equipped with a canopy /C as
standard.
On request, the motor can be delivered without canopy. In this case, you have to
install a cover when you install the drive in the plant/machine in order to prevent
objects from falling into the ventilation openings. Observe the requirements accord-
ing to EN / IEC 60079-0 and EN / IEC 60079-7. This cover must not obstruct the
cooling air supply.
In mounting positions with the motor output shaft pointing upwards (e.g. M2/V3), a
suitable cover must prevent small objects from falling through the fan guard, see
also EN / IEC 60079-0. This cover must not obstruct the cooling air supply.