18
Operating Instructions – Explosion-Proof AC Motors DR63/eDR63, DVE250/280
4
Motor installation notes
Mechanical Installation
The drying process is finished when the minimum insulation resistance has been ex-
ceeded.
In the terminal box, make sure that:
The inside is clean and dry
The connections and fixing parts are free from corrosion
The gasket and sealing surfaces are in good condition
The cable glands are tight, otherwise clean or replace them
4.3 Motor installation notes
Motor shaft ends must be thoroughly cleaned of anti-corrosion agents, contamination
or similar (use a commercially available solvent). Do not allow the solvent to pene-
trate the bearings or shaft seals – this could damage the material.
Mount the gearmotor only on a level, vibration-free and torsionally rigid support struc-
ture.
Make sure the customer's counter-bearing is unobstructed and can move freely.
Align the motor and the driven machine carefully in order to prevent the output shaft
from being exposed to unacceptable strain. Observe the permitted overhung and
axial forces.
Do not jolt or hammer the shaft end.
CAUTION
Sharp edges due to open keyway.
Minor injuries.
Insert key in keyway.
Pull protective sleeve over shaft.
CAUTION
Improper mounting may result in damage to the motor.
Possible damage to property
Observe the following notes.
NOTICE
The mounting position for installation must correspond with the specifications on the
nameplate.

Table of Contents