EasyManua.ls Logo

SEW-Eurodrive DR63 Series - Use

SEW-Eurodrive DR63 Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
Operating Instructions – Explosion-Proof AC Motors DR63/eDR63, DVE250/280
6
Use
Duty Types and Limit Values
6.2 Use
6.2.1 Motors of category 2G and 2GD
The necessary information for this is listed on the nameplate.
NOTES ON EXPLOSION PROTECTION
It is not permitted to connect more than one motor to one frequency inverter.
The voltage at the motor terminal board must projected be to prevent overheating.
If the motor voltage is too low (undercompensation), slip increases, which causes
higher temperatures in the rotor of the motor.
If the mechanical load is the same, operation on a frequency inverter causes a
more significant motor temperature rise due to the harmonic content in current and
voltage.
NOTES ON EXPLOSION PROTECTION
The frequency inverter can only be operated with motors that are permitted for this
operating mode according to the EC prototype test certificate.
Verification that the motor voltage matches the specifications of the EC prototype
test certificate must be provided during startup.
P
i
f
kVA
Hz
n

Table of Contents