EasyManua.ls Logo

Sewha SI 410 - F-FUNCTION LIST; F-Function List (Continued)

Sewha SI 410
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 31 -
536
Auto tare set when weighing
starts
00
00: Disuse
01: Use
537
Tare reset Timing
00
00 : Manual
01 : Auto at empty range
02 : Auto at steady condition
03 : Auto when finish relay out is off
538
Auto Tare reset Time
00
00 : Disuse
00 ~ 09 : use (Unit : 1sec)
540
Hold Mode
00
00: Sample Hold
01: Peak Hold
02: Average Hold
541
Auto Hold set
00
00 : Disuse
01 : Use (Activate when weight is over near
zero range with stable)
542
Hold Delay Time
00
00 : Disuse
01 ~ 10 : Use (Unit : 1sec)
543
Hold reset at the near zero
00
00: Disuse
01: Use
544
Hold reset delay time
00
00 : Disuse
01 ~ 10 : Use (Unit : 1sec)
545
Average Hold Time
10
01~99(Unit: 01sec)
Hold average weight during set time
550
Set point save
00
00 : Apply to current P/N
01 : Apply to every P/N
551
Drib Control
00
00: Disuse
01: Use