◆ Weighing mode 3. - Checker mode 1. (500-03) – Simple comparison mode 1.
Time
Time
Contents
t1
Finish Relay Output Delay Time (Function 510)
When Function 102-3 or 102-6, save the date after t3 time.
t2
Finish Relay Output Time (Function 520)
Relay output
Relay
Condition
Relay
Condition
OUT 1
Near zero < Steady weight ≤ SP1 (ON)
OUT 4
SP3 < Steady weight ≤ SP4 (ON)
OUT 2
SP1 < Steady weight ≤ SP2 (ON)
OUT 5
SP4 < Steady weight (ON)
OUT 3
SP2 < Steady weight ≤ SP3 (ON)
OUT 6
Within near zero range
(Function HF29) (ON)