EasyManua.ls Logo

Shark 250 User Manual

Shark 250
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Doc# E169703 V.1.02 QS - 1
Shark® 250 Meter Quickstart
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Shark® 250 Meter Quickstart Guide
Mechanical Installation:
Electrical Installation: Select diagram for your application.
NOTE: Other wiring configurations are available. See the full User Manual on the enclosed CD.
DIN mounting
bracket
Top mounting
bracket groove
Bottom
mounting
bk
DIN Mounting brackets
Remove (unscrew) ANSI studs
for DIN installation
DIN Installation
92mm Square
form
ANSI Installation
ANSI Studs
4.0” Round form
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
3 x 0.1A
FUSE
3A
C
C
B
B
A
A
N
N
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
3 x 0.1A
FUSE
3A
C
C
B
B
A
A
N
N
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
2 x 0.1A
FUSE
3A
C
C
B
B
A
A
WYE direct, 3
phase, 4 wire
Delta direct, 3
phase, 3 wire
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
3 x 0.1A
FUSE
3A
C
C
B
B
A
A
NOTE: Do not overtighten nuts. The maximum installation torque is 0.4 Newton-Meter.
WYE with PTs,
3 phase, 4 wire
Delta with PTs, 3
phase, 3 wire
Question and Answer IconNeed help?

Do you have a question about the Shark 250 and is the answer not in the manual?

Shark 250 Specifications

General IconGeneral
BrandShark
Model250
CategoryMeasuring Instruments
LanguageEnglish

Summary

Mechanical Installation

ANSI Mounting Installation

Details the ANSI mounting method for the Shark® 250 meter.

DIN Mounting Installation

Details the DIN mounting method for the Shark® 250 meter.

Electrical Installation Diagrams

Program Faceplate Settings

Access Configuration Mode

Guides users through entering configuration mode via the meter's faceplate buttons.

Save Meter Settings

Connect Meter via USB

Device Status and Profile Access

Configure CT and PT Ratios

Set CT Ratios

Inputting primary and secondary values for Current Transformer (CT) ratios in the meter software.

Set PT Ratios

Inputting primary and secondary values for Potential Transformer (PT) ratios in the meter software.

Configure System Wiring and Settings

Configure Communications Settings

Program Meter Time

Program Meter Name/Designation

Update Device Settings

Related product manuals