AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 15
SW
NO.
Data
No.
Item Switch selection and contents of functions Initial value Remark
S
W
68
1 Line open delay time in
dial test
Bit No. 1 2
2sec
02sec 0 0
3sec 0 1
2 4sec 1 0
0
5sec 1 1
3 Inhibited to use 0
4 0
5 T1 timer setup Binary input
40sec
0
6 Bit No.
Set range
5678
30 to 105sec
5sec interval
0
7 1
8 0
S
W
69
1 Inhibited to use 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
S
W
70
1 Inhibited to use 0
2 1
3 0
4 Reception waiting time
between frames
1: 4.4sec 0: 3.4sec
3.4sec 0
5 Preamble send time of
300bps
Bit No. 5 6
1.0sec
00.5sec 0 0
1.0sec 0 1
6 1.5sec 1 0
1
2.0sec 1 1
7 RCP send times Bit No. 7 8
3 times
03 times 0 0
6 times 0 1
89 times10
0
12 times 1 1
S
W
71
1 Inhibited to use 0
2 0
3 0
4 0
5 1
6 1
7
0
8 0
S
W
72
1 EYE-Q check 1: EYE-Q check only 0: 0 reception & EYE-Q
check
0 reception &
EYE-Q check
0
2 ERR frame reception
operation
1: Continues process. 0: Not continue process.
(Error)
Not continue
process. (Error)
0
3 Waiting time for CED/
ANSam send start
Bit No. 3 4
2.25sec
0
When a value outside
the set range is set,
the initial value is set.
2.25sec 0 0
4 3sec 0 1
0
4sec 1 0
5 RTC EOL send times 1: 6 times 0: 7 times 6 times 1
6 Inhibited to use 0
7 CNG send start Bit No. 7 8
0.5sec
0
When a value outside
the set range is set,
the initial value is set.
0.5sec 0 0
8 1.0sec 0 1
0
1.5sec 1 0