Main
code
Sub
code
Contents Details of operation
Initial
value
Set range
50 18 Duplex memory reverse
position adjustment
<Only when an duplex
function is installed>
After completion of warmup, shading is performed and currently set
value is displayed
58 1 99
50 19 Duplex rear edge void
adjustment
<Only when an duplex
function is installed>
After completion of warmup, shading is performed and currently set
value is displayed.
37
52
70
1 99
51 2 Resist amount adjustment After completion of warmup, shading is performed and the currently set
resist amount adjustment value is displayed.
50
1
50
50
48
1 99
(6 94 for
the duplex
only)
63 1 Shading data check The copy lamp is shifted to the shading position and it is lighted with the
reference voltage at AD conversion fixed (Vref– = 0.5V, Vref+ = 4.5V).
The level of one pixel at the center at that time is displayed.
64 1 Self print mode Disregards the optical system and performs self printing in 1 by 2mode.
67 14 Printer Flash ROM
Data Download
<Only when printer
function is installed>
The machine enters the version up mode of the printer control PWB
flash ROM.
For details, refer to the later.
Key operation
Memory reverse position adjustment value:
Copy quantity keys
Key operation Display
Adjustment mode select:
Exposure mode select key
Auto: SPF/R-SPF rear edge void
Set value:
Copy quantity keys
Manual: R-SPF off center
Photo: R-SPF lead edge void
Key operation Display
Resist amount adjustment:
Copy quantity keys
Adjustment mode select:
Exposure mode select key
Auto: Main cassette
Manual: 2nd tray
Photo: Manual feed tray
Auto + Manual: Duplex <Only AR-206/207>
Auto + Photo: RSPF <Only when an
option is installed>
Display
Display section: Shading data
AR-162 SIMULATIONS – 12