AR-5618S SIMULATIONS 7-6
10 - Toner motor operation When the [START] key is pressed, the toner motor is driven for 30 sec.
After completion of the process, the machine goes into the main code input standby mode.
When the [Interrupt] key is pressed, the machine goes into the main code input standby mode.
14 - Trouble cancel (except for U2) * Trouble to write into the EEPROM such as H trouble is canceled and hardware reset is
performed.
16 - U2 trouble cancel * U2 trouble is canceled and hardware reset is performed.
20 01 Maintenance counter clear When the [START] key is pressed, the maintenance count value is cleared and "000000" is
displayed. (Alternate display of "000" and "000")
21 01 Maintenance cycle setting The current set maintenance cycle code is displayed (initial display), and the set data are stored.
02 Mini maintenance cycle setting
(Valid only when the destination is
set to Japan AB series.)
The current set maintenance cycle code is displayed (initial display), and the set data are stored.
22 01 Maintenance counter display The maintenance counter value is displayed.
02 Maintenance preset display (Valid
only when the destination is set to
EX Japan)
The copy quantity corresponding to the code that is set with SIM21-01 is displayed.
(For example: 50,000 sheets)
03 Jam memory display The LED of the latest jam position is lighted. Every time when the [PRESET RATIO selector] keys is
pressed, the jam memory data is acquired sequentially from the latest. The jam position is judged by
the acquired data and the corresponding LED is lighted. The 7-seg display indicates the jam number.
At that time, "A" is displayed on the upper first digit. When the last one is displayed, the latest one will
be displayed again. Max. 30 jams from the latest are stored. When the [Interrupt] key is pressed, the
machine goes into the sub code input standby mode. When the [CA] key is pressed, the simulation is
terminated.
04 Jam total counter display The jam total counter value is displayed.
05 Total counter display The total counter value is displayed.
06 Developing counter display The developing counter data is acquired and displayed on the 7-seg display.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
07 Mini maintenance preset display
(Valid only when the destination is
set to Japan AB series)
The mini maintenance cycle data is acquired and displayed on the 7-seg display.
When the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
08 SPF counter display The SPF counter value is displayed.
09 Paper feed counter display The counter value of the selected paper feed section is acquired from each variable, the data is
displayed on the 7-seg display according to the regulations. When this simulation is executed, the
value of the 1st paper tray is displayed first. Press the [TRAY SETTING] key to select the tray. When
the [Interrupt] key is pressed, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
12 Drum counter display The drum counter and the drum rotating time are displayed.
To change the display mode, press the [AUTO/TEXT/PHOTO] key.
13 CRUM destination display When this simulation is executed, the CRUM destination set (written) in the CRUM chip is displayed.
This simulation is valid only for the models where the CRUM is valid.
Main
code
Sub
code
Contents Details of operation
Code Setting
0
1
2
3
4
5
5,000 sheets
7,500 sheets
10,000 sheets
25,000 sheets
50,000 sheets * Default
Free (999,999 sheets)
Code Setting
0
1
2
5,000 sheets * Default
10,000 sheets
Free (999,999 sheets)
LED Display mode
AUTO exposure indicator
TEXT indicator
Drum counter
Drum rotating time
7-seg display Meaning (CRUM destination) 7-seg display Meaning (CRUM destination)
00
01
02
03
Not set yet
BTA-A
BTA-B
BTA-C
04
05
06
99
CHN-A
JPN_A
BTA_F
Conversion

Other manuals for Sharp AR-5620N

Related product manuals