AR-M236/M276/M237/M277 SIMULATION 8 - 25
Note: Executable only when the PCL/PS3 is installed.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
Note: Setup is allowed only for Japan and UK.
Operation/procedure
Select the display language (language code) with the 10-key according
to the table below, and press the [START] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure
Input the set value with the 10-key and press the [START] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure
Enter the set value with 10-key, and press [START] key.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
Note: Executable only with SRU (AR models).
26-18
Purpose Setting
Function
(Purpose)
Used to set enable/disable of toner save operation.
Item Specifications Operation mode (Common)
Item Content
Setting
range
Default
0
OFF
Disable 0-1 0
1
ON
Enable
26-22
Purpose Setting
Function
(Purpose)
Used to set the specification (language display) for the
destination.
Item Specifications
Item
Language
code
ASIC
expression
Remarks
0 JAPANESE ja 6A 61
1 ENG.US en 65 6E
2 ENG.UK gb 67 62
3 FRENCH fr 66 72
4 GERMAN de 64 65
5 ITALY it 69 74
6 DUTCH nl 6E 6C
7 SWEDISH sv 73 76
8 SPANISH es 65 73
9 PORTUGUESE pt 70 74
10 TURKISH tr 74 72
11 GREEK el 65 6C
12 POLISH pl 70 6C
13 HUNGARIAN hu 68 75
14 CZECH cs 63 73
15 RUSSIAN ru 72 75
16 FINNISH fi 66 69
17 NORWEGIAN no 6E 6F
18 DANISH da 64 61
19 CHINESE zh 7A 68
20 TAIWANESE tw 74 77 Traditional Chinese
supported locally
21 SLOVAK sk 73 6B
22 HEBREW he 68 65 Supported locally
26-30
Purpose Setting
Function
(Purpose)
Used to set ON/OFF of the heater lamp slow-up
control conforming to the CE mark control.
Item Specifications Operation mode (Common)
Item
Default
Japan, SEC, SECL,
SCA, SEF, Taiwan
Others
0
OFF
01
1
ON
26-35
Purpose Setup
Function
(Purpose)
Used to set whether the same continuous troubles are
displayed as one trouble or the series of troubles with
SIM 22-4 when the same troubles occur continuously.
Item Specifications
Item Content Default
0
ONCE
When two or more troubles occur, only one
is registered.
0
1
ANY
All the troubles occurred are registered.
26-36
Purpose Setting
Function
(Purpose)
Used to set whether the machine is stopped or not
when the maintenance counter life is expired.
Item Operation
Item Content Default
0STOP Stop 1
1 NON STOP Non stop