GB-3
ENGLISH
30 cm
30 cm
30 cm
LOCATION
• The unit should be placed on a rm foundation to
minimize noise and vibration. For safe and secure
positioning, place the unit on a smooth, level oor
strong enough to support the unit. This will also
help to avoid water spilling out into the room
The unit has casters to aid placement, but it
should only be rolled on smooth, flat surfaces.
Use caution when rolling on carpet surfaces. Do
not attempt to roll the unit over objects.
• The unit must be placed within reach of a properly
rated grounded socket.
• Never place any obstacles around the air inlet or
outlet of the unit.
• Allow at least 30 cm of space from the wall for ef-
cient air-conditioning.
• Be sure to turn the unit off and disconnect the power plug from the wall socket before
performing any maintenance or cleaning. A fan is rotating inside the unit and you may get
injured.
• Place the unit on a level surface to avoid water spilling out into the room.
• Make sure to connect the air conditioner to power supply of the rated voltage and fre-
quency. Use of a power supply with improper voltage and frequency can result in equip-
ment damage and possible re.
• Do not use the unit in a place where inammable gas may leak. It may cause re.
Use the unit in a place with minimal dust, fumes and moisture in the air.
• Make sure a leak breaker or a circuit breaker is installed, depending on the installation
location, to avoid electrical shock.
• Install an earth leakage breaker to avoid electric shock in case of leak.
Use the current-activated, high-sensitivity, high-speed type breaker with a rated sensitivity
current of below 30 mA and an operating time of below 0.1 second.
Exhaust hose
1
Insect guard net
1
Manual
1
Window adapter
1
Remote control
1
Rain guard
2
Battery
(R03)
2
INCLUDED
01_CV-P10PR_OM_EN.indd 3 14/08/29 16:42

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp CV-P10PR and is the answer not in the manual?

Sharp CV-P10PR Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
Hose length1.5 m
Noise level52 dB
Hose diameter140 mm
Ionic functionYes
Number of speeds3
Airflow (high speed)34.8 m³/h
Cooling capacity (max)- BTU/h
Dehumidifying capacity1 l/h
Timer duration (maximum)12 h
Air conditioner functionsCooling, Dehumidifying, Ventilating
Cooling capacity in watts (max)2500 W
Cooling capacity in watts (nominal)- W
Cooling energy efficiency (EER, W/W)-
Connected load960 W
AC input voltage220-240 V
AC input frequency50 Hz
Annual energy consumption (cooling)- kWh
Product colorSilver
Weight and Dimensions IconWeight and Dimensions
Depth450 mm
Width500 mm
Height830 mm
Weight42000 g