[Adjustment standard value]
Measuring instrument: [TOPCON SR-UL2] Technical measuring instrument.
Level Reference value Adjustment spec Inspection spec
Point 7 928
X=0.272
±0.0010 ±0.0020
y=0.277
Point 6 784
X=0.2755
±0.0015 ±0.0030
y=0.2720
Point 5 624
X=0.2755
±0.0020 ±0.0040
y=0.2720
Point 4 432
X=0.2755
±0.0030 ±0.0060
y=0.2720
Point 3 304
X=0.2755
±0.0035 ±0.0070
y=0.2720
Point 2 192
X=0.2755
±0.0040 ±0.0080
y=0.2720
Remarks Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Brightness specification after adjustment.
LC-60SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2
LC-70SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2