Page #29 background imageLoading...
Page #29 background image
LC-60LE822E/LC-60LE822ERU
6 – 7
8. Special features
1. NORMAL STANDBY CAUSE (Page 1/21)
Display of a cause (code) of the last standby.
The cause of the last standby is recorded in EEPROM whenever it is possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
2. EEP SAVE (Page 21/21)
Storage of EEP adjustment value
3. EEP RECOVER (Page 21/21)
Retrieval of EEP adjustment value from storage area.
4. MONITOR ERR CAUSE (Page 1/21)
Display of a cause (code) of Error from sub-Microcomputer.
The cause of Error is recorded in EEPROM whenever it is possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
1) This displays Error code and time when the error occurred.
The latest error is displayed on “1)”
The error that happens ahead of “1)” is displayed on “2)”.
2) The character depends on the way how to acquire Time Information
Example) In this example, it is shown that the error occurred 3 times.
21/21
1 EEP SAVE OFF Writing setting values to EEPROM.
2 EEP RECOVER OFF Reading setting values from EEPROM.
3 MONITOR ERROR CAUSE RESET OFF Reset of monitor error cause
4 MODEL NAME LE705 MODEL NAME
5 PANEL SIZE 40 Panel size setting. (40/46/52)
6 SHORT CHECK MODE Enter Check LED Back light
7 SHORT CHECK CURRENT 60
8 CURRENT SW LOW
9 PRODUCT EEP ADR 0x 0 Don't touch when serving (for producer of factory)
10 PRODUCT EEP DATA 0x 0 Don't touch when serving (for producer of factory)
11 PRODUCT FACTORY 1 Don't touch when serving (for producer of factory)
T: Time is acquired from digital broadcasting
This doesn't contain “Time offset” which is considered a time difference and Daylight-Saving Time, etc. ...
U: Time is acquired from analog broadcasting (teletext)
B: Accumulation time of Backlight
In the case that Time information cannot be acquired, “B” is displayed.
1) 16 T07/01/01 12:03 Error code: 16 (lamp error) Time: 07/01/01 12:03
* It is latest Error.
* Time is acquired from digital broadcasting.
* Time is UTC which doesn't have Time offset.
2) 16 U01/01/01 04:07 Error code: 16 (lamp error) Time: 07/01/01 04:07
* It is Error that happens ahead of “1)”.
* Time is acquired from analogue broadcasting.
3) 16 B00000004:11 Error code: 16 (lamp error) Accumulation time: It is displayed that 4:11 have passed after Backlight driving.
* It is Error that happens ahead of “2)”.
4) 00 0000000000000 No error (“00” shows that the error is not occurred.)
Page Line Item Description Remarks (adjustment detail, etc.)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp LC-60LE822E and is the answer not in the manual?

Sharp LC-60LE822E Specifications

General IconGeneral
Power supply typeAC
Power consumption (standby)0.20 W
Power consumption (typical)100 W
Child lockNo
Plug and PlayYes
Audio formats supportedAAC
Video formats supportedH.264, MPEG4
Display diagonal60 \
Display technologyLCD
Native aspect ratio16:9
Native refresh rate100 Hz
Viewing angle, horizontal176 °
Internal memory8000 MB
Audio (L/R) in0
HDMI ports quantity4
SCART ports quantity1
Product colorBlack
LED indicatorsStand-by
Panel mounting interface400 x 400 mm
Remote control typeGA841WJSA
RMS rated power20 W
Number of speakers2
Tuner typeAnalog & digital
Analog signal format systemNTSC, PAL, SECAM
Weight and Dimensions IconWeight and Dimensions
Depth (with stand)368 mm
Width (with stand)1439 mm
Height (with stand)975 mm
Weight (with stand)51000 g
Depth (without stand)40 mm
Height (without stand)913 mm

Related product manuals