MX-M260/M310/M260N/M310N  SIMULATION 6 - 10
Operation/procedure
1. Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
2. The warm-up time is counted up and displayed in the unit of sec.
If the [CA] key is pressed at this time, count-up is interrupted to ter-
minate the simulation. (However, warm-up is continued.)
3. After completion of warming up, “WARM UP COMPLETED” is dis-
played and the control returns to the initial screen.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key. 
3. Press the [START] key. 
Output is made with the entered value, and the display returns to the 
original state.
(
∗) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
The minimum increment is 10V.
The result of (Set value) -200/ 10 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value
*10+200) is used as the set value.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
Output is made with the entered value for 30sec, and the display 
returns to the original state.
Min. unit: 10V increment
(
∗) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
Operation/procedure
1. Touch the exposure mode to be changed.
The current set value is displayed.
2. Enter the set value with the 10-key.
3. Press the [START] key.
7-8
Purpose Setting/Operation test/check
Function 
(Purpose)
Used to set the display of the warm-up time.
Item Operation
8
8-1
Purpose Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the 
developing bias voltage in each copy mode and the 
control circuit.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper
Item Content
Setting 
range
Default
1 AE (145)  AE (145mm/s) 
200-
650
450
2 TEXT (145)  Character (145mm/s)  450
3 TEXT/PHOTO (145) 
Character/Photo 
(145mm/s) 
450
4 PHOTO (145)  Photo (145mm/s)  450
5 TONER SAVE (145)  Toner save (145mm/s)  400 
6 AE (122)  AE (122mm/s)  450
7 TEXT (122)  Character (122mm/s)  450
8 TEXT/PHOTO (122) 
Character/Photo 
(122mm/s) 
450
9 PHOTO (122)  Photo (122mm/s)  450
10 TONER SAVE (122)  Toner save (122mm/s)  400
8-2
Purpose Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the main 
charger grid voltage in each copy mode and the control 
circuit.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Photo conductor
Item Content
Setting 
range
Default
1 AE (145)  AE (145mm/s) 
350-
750
590
2 TEXT (145)  Character (145mm/s)  590
3 TEXT/PHOTO (145) 
Character/Photo 
(145mm/s) 
590
4 PHOTO (145)  Photo (145mm/s)  590
5 TONER SAVE (145)  Toner save (145mm/s)  540
6 AE (122)  AE (122mm/s)  590
7 TEXT (122)  Character (122mm/s)  590
8 TEXT/PHOTO (122) 
Character/Photo 
(122mm/s) 
590
9 PHOTO (122)  Photo (122mm/s)  590
10 TONER SAVE (122)  Toner save (122mm/s)  540
8-10
Purpose Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the 
developing bias voltage in each printer mode and the 
control circuit.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Developer/Toner hopper