MX-M260/M310/M260N/M310N SIMULATION 6 - 20
Operation/procedure
Input the set value with the 10-key and press the [START] key.
This setup varies in connection with SIM 26-6 (Destination setup).
Operation/procedure
Enter the set value with 10-key, and press [START] key.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
Note: Executable only with SRU (AR models).
Operation/procedure
Enter the set value with the 10-key, and press the [START] key.
Operation/procedure
Sets enable/disable of the gamma life correction function.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
Operation/procedure
Input the set value with the 10-key and press the [START] key.
This setup varies in connection with SIM 26-6 (Destination setup).
26-30
Purpose Setting
Function
(Purpose)
Used to set ON/OFF of the heater lamp slow-up control
conforming to the CE mark control.
Item Specifications Operation mode (Common)
Item
Default
U.S.A, Canada, Australia, France, Taiwan Others
0
OFF
01
1
ON
26-35
Purpose Setup
Function
(Purpose)
Used to set whether the same continuous troubles are
displayed as one trouble or the series of troubles with
SIM 22-4 when the same troubles occur continuously.
Item Specifications
Item Content Default
0
ONCE
When two or more troubles occur, only one is
registered.
0
1
ANY
All the troubles occurred are registered.
26-36
Purpose Setting
Function
(Purpose)
Used to set whether the machine is stopped or not
when the maintenance counter life is expired.
Item Operation
Item Content Default
0STOP Stop
1
1 NON STOP Non stop
26-50
Purpose Setting
Function
(Purpose)
Used to set ON/OFF of the black and white reversion
function.
Item Operation
Item Content Default
0ON
Enable 1 (U.K.)
0 (Others)
1OFF
Disable
26-56
Purpose Setting
Function (Purpose) Gamma life correction setting
Item Operation
Item Set value Default
1 AE (Japan)
0: Disable
1: Enable
0
2 AE (Ex Japan) 0
3Text 1
4 Text/Photo 1
5 Photo (Error diffusion) 1
6 Photo (Dither) 1
7 T/S AE (Japan) 0
8 T/S AE (Ex Japan) 0
9 T/S Text 1
10 T/S Text/Photo 1
26-57
Purpose Setting
Function (Purpose) Used to set the model code.
Item Operation
Item Default
1 MX-M260N
1
2 MX-M310N
3 MX-M260
4 MX-M310
5 MX-M260FG
6 MX-M260FP
7 MX-M310FG
8 MX-M310FP
26-60
Purpose Setting
Function
(Purpose)
Used to set enable/disable of the FAX mode key when
FAX is not installed. (When FAX is installed, the FAX
mode is enabled regardless of this setup.)
Item Operation
Item Content
Default
U.S.A, Canada,
U.K., Australia
Others
0ON
Effective (The message with
FAX uninstalled is displayed.) 0 1
1 OFF Disable (Error Beep)