Ml-5600
MZ-5600 interconnection example
SD
===:::::::=--=::::::::::~~-
SD
RD
---
RD
RS
CS
-
READ~Y--==~--~=--
DR
:::::::::::=_::::::::-::-
ER
SG
--------
SG
Functionallpeclflcations
(Electrical charactariltics)
Fig. 58
Control signall: RS,
CS,
READY, OR, ER,
CP,
Cl, ST1,
ST2,
and RT \
On voltage: +5
to
+15V
Off
voltage:
-5
to
-15V
Data signals;
SO
and
RD
Mark:
-5
to
-15V
Space:
+5to+15V
Baud rate:
110, 150, 200,
300,
600, 1200, 2400,
4BOO,
or
9600
bauds
Word length: 7 or B bits
Parity: Even, odd, or none
Stop bit: One bit, one and Half, two bit
Protocol:
Start-stop asynchronous non-proto<:ol
MZ5600
between MZ3500 connection
MZ5600 MZ3500
SD
RD
SD
RD------
CS
READY----
DR-----
ER
---y--
GND-----
CS
READY
OR
ER
PO
GND
Others are OPEN
Dip SW
5
ON
6 ON
7
OFF
Software EXP.) BASIC 3
[MZ6500, MZ5500]
~
[MZ3500]
10
CHANNEL
1,9600,
"SN2"
}
20
SEND "MZ-5500"; "@";
30
END
10
20
30
40
CHANNEL
0,
9600,
"SN2"
}
RCV
A$,
0,
"@"
A$ = LEFT$ (A$,
LEN
A$-1)
DISP
A$=
END
[MZ3500]
~
[MZ5500]
10
CHANNEL
0,
9600,
"SN2"
20 SEND "MZ-3500"; "@";
30
END
}
MZ5600
MZ3500
MZ3500
-50-
10
20
30
40
CHANNEL
1,9600,
"SN2"
}
RCV
A$,
0,
"@"
A$ = LEFT$ (A$,
LEN
A$-1)
DISPA$=
END
MZ5600
12-4 Z80A SIO (LH0084A) Pin configuration
SV
GND
J6
INTERRUPT
IEI
CONTROL
IEO
RXDA
RiCA
TXDA
"'I'XCA
n'Rn
WIROYA
CH-A
~}
IIODEII
1i'RA
CONTROL
~
RXDB
~
TXDB
~
W7iiiVIi
~
1I0DEII
DTRB CONTROL
DCDB
CH-B
g~~~
{TIlT
5
L..----,
__
...-..J
i'mi)
DO-D7:
B/A:
CID:
CE:
M1
:
10Ra:
RD:
RESET:
IEI:
IEO:
M:
W/RDY
A.
W/RDYB:
CTSA, CTSB:
DCDA, DCDB:
RXDA, RXDB:
TXDA, TXDB:
RXCA, RXCB:
SYNCA, SYNCB:
C/O
B/A
Fig. 59
System data bus used for data or
command transfer between the
CPU
and
ZBO
SIO.
Channel
A or B select (high for
B,
low for A).
Control (command) or data select
(high for
control, low for data).
Chip enable
Machine cycle
1
I/O request
Read cycle status
Reset
Interrupt enable input
Interrupt
enable
output
Interrupt request
Wait/Ready
A, Wait/Ready B
Indicate send ready.
Data carrier detect; indicate send/
receive ready.
Received data.
Send data
Receiver clock.
In
the synchronous
mode, the
RXC
has the same rate
(frequency)
as
the baud rate used.
In
the asynchronous mode, the RXe
has a rate which
is
a multiple
of
the
baud rate used: i.e.
1, 16, or 64 times
the baud rate depending on the mode
instruction.
Transmitter
clock; functionaly the
same
as
RXC,
for transmission.
Request
to
Send
to
periphera
devices.
Data Terminal Ready sent
to
peri·
pheral
devices.
Synchronization
signal input

Other manuals for Sharp MZ-5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp MZ-5500 and is the answer not in the manual?

Sharp MZ-5500 Specifications

General IconGeneral
BrandSharp
ModelMZ-5500
CategoryDesktop
LanguageEnglish

Related product manuals