12. OPTION RAM INTERFACE
1) INTERFACE
The expanded RAM connector terminals are shown in the table below.
The 40-pin RAM is used for the connector.
Extension RAM connector terminals
Signal Name Pin No. Pin No. Signal Name
+5V 1 2 N.C.
HWR 3 4 N.C.
GND 5 6 A21
A20 7 8 A19
A18 9 10 A17
A16 11 12 A15
A14 13 14 A13
A12 15 16 A11
A10 17 18 A9
A8 19 20 A7
A6 21 22 A5
A4 23 24 A3
A2 25 26 A1
A0 27 28
RD
D7 29 30 D6
D5 31 32 D4
D3 33 34 D2
D1 35 36 D0
RASPN2 37 38 VCKDC
GND 39 40 GND
13. RESET SEQUENCE
The reset sequence block diagram is shown below. Note that the
RESET signal (system reset) and CKDCR signal (CKDC reset) are
different from each other.
1) POWER ON/OFF
The flow of signal processing at the time of the power supply turning
On/Off is as follows:
Table 19<Power OFF>
Power supply MPCA9 CPU CKDC9
1
POFF L
2
IRQ0 L
3
STOP L
4
RESET L
(System reset)
Table 20<Power ON>
Power supply MPCA9 CPU CKDC9
1
POFF H
2
STOP H
3
RESET H
(System reset)
The table below shows the timing chart.
14. DRAWER
The UP-600 can use up to 2 optional external drawers.
1) DRAWER SOLENOID DRIVE
P34 P37 inside the CPU are allocated for the port output of the
drawer solenoid drive.
Built-in port Signal name Remarks
P34
DR0 Drawer 1 (optional drawer)
P35
DR1 Drawer 2 (optional drawer)
P36
DR2 Reserved
P37
DR3 Reserved
One port corresponds to one drawer. If a power failure is detected,
the drawer solenoid drive must be stopped as soon as possible.
The drawer solenoid drive time must be controlled in the range of
40 ms to 50 ms by the timer.
2) DRAWER OPEN/CLOSE SENSE
The drawer open/close sense signal is input into the built-in port of
the CPU. The sense signal of an optional drawer sensor is also wired
ORed before inputting.
P33=1: Any of the drawers is open.
POFF
CKDCR
(CKDC reset)
VCC
POFF
INT0
IRQ0
STOP
RESET
(System reset)
SLIDE
SW
CKDC9
MPCA9
POWER
SUPPLY
CPU
PG GOOD
RESET
STOP
SHEN
SCK
+5V,+12V
(POFF)
10ms MIN
8 PULSE
(System)
Power supply On Power supply Off