(4) RS-232C start code and end code
*A-C: Start code 000-127 (default: 002)
D-F: End code 000-127 (default: 013)
(5) RS-232C time out setting
Default: 007
Thermal printer density
* 50 is the default setting. To make the print darker, set a larger number, and to make the print lighter, set a
smaller number.
Language selection
*Language: 0: English 2: French 3: Spanish (default: English)
When you change the language, the texts such as clerk names, logo messages and function texts
(refer to page 45), which you programmed, will be reset to the default settings. The language
selection must be made before programming clerk names, logo messages and function texts.
s
88
@
2
A
PrintKey operation example
s @
*Language
(0, 2 or 3)
A
To set “0”
88
s
50
@
00
sA
PrintKey operation example
s @
*Printer density
(00-99)
As
To set “0”
50
s
35
@
30
sA
PrintKey operation example
s @
Time out (1 to 255 sec.)
As
35
s @
*ABCDEF
As
To set “000000”