Maintenance indicator
Problem
Cause Possible solution
Temperature
warning
indicator
Normal
Off
Red on
(Standby)
The internal
temperature is
abnormally high.
Abnormal
Blocked air intake
Relocate the projector to an area
with proper ventilation.
Cooling fan break-
down
Internal circuit failure
Clogged air intake
Clogged intake vent
cover
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center for repair.
Clean the air vents and the intake
vent cover.
Lamp
indicators
1, 2
Red on
(Standby)
The lamp does
not illuminate.
Burnt-out lamp
Lamp circuit failure
Carefully replace the lamp.
Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center for repair.
Please exercise care when
replacing the lamp.
Red on
Time to change
the lamp.
Remaining lamp life
becomes 5% or less.
Green on
Green blinks
when the lamp
is warming up.
Info
If the temperature warning indicator blinks and the projector enters the standby mode, the temperature
warning indicator starts to illuminate. Check whether any of the ventilation holes are blocked
and then try turning the power back on. Wait until the projector has cooled down completely before plugging
in the power cord and turning the power back on. (At least 10 minutes.)
If the power is turned off for a brief moment due to power outage or some other cause while using the
projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red
and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power
cord in the AC outlet and then turn the power on again.
The cooling fan keeps the internal temperature of the projector constant and this function is controlled
automatically. The sound of the cooling fan may change during operation because the fan speed may
change and this is not a malfunction.
The lamp does
not illuminate.
The lamp is shut
down abnormally.
Disconnect the power cord from
the AC outlet, and then connect it
again.
Power
indicator
Green on/
Red on
Red
blinks
The power
indicator blinks in
redwhenthe
projector is on.
The intake vent
cover is open.
Securely install the cover.
If the power indicator blinks even
when the intake vent cover is
securely installed, contact your
nearest Sharp Authorized Projector
Dealer or Service Center for
advice.

Table of Contents

Other manuals for Sharp XG-PH70X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp XG-PH70X and is the answer not in the manual?

Sharp XG-PH70X Specifications

General IconGeneral
BrandSharp
ModelXG-PH70X
CategoryProjector
LanguageEnglish

Related product manuals