47
Dealer’s Manual (SG-C7050-5V / SG-C7050-5R / SG-C7050-5C / SG-C7050-5D)
Return to index page
https://si.shimano.com/DM/CASG003
Click here for the latest Dealer's Manual
1
(z)
Fill the container with maintenance oil
to a height of 95 mm.
(z)
95 mm
2
(z)
Immerse the internal unit in the oil from
the left side until the oil reaches up to
ring gear unit 1, as shown in the
illustration.
(z)
Ring gear unit 1
3
Keep the internal unit immersed for
approximately 90 seconds.
4
Remove the internal unit from the oil.
5
Let excess oil drain off for approximately
60 seconds.