F.04
Mixing mode
The number of layers of mixing action when it starts mixing.
For example: the suction time is 20sec, the mixing proportion
is 10%, the number of layers is 2, and then the mixing action
is 9s—1s ----9s---1s
Set single layer’s working, and the suction time range is 5-99
secs.
Set double layers’ working, and the suction time range is
17-99 secs.
Set three layers’ working, and the suction time range is 32-99
secs.
Set four layers’ working, and the suction time range is 46-99
secs.
If the suction time changes, the min. action time is less than
1 sec. after calculation, and the program will force to change
the action time to 1 sec.
1 1-4times
F.05
Mixing action count cycle start setting
Count from the first start-up, and start once mixing action
after several times of repeated suction startings.
Set 1 as mixing materials every time.
Set [F.03] to 0 without mixing.
once 1-9 times
F.06
Setting time of cleaning before suction
Set 0 as the no screen cleaning before suction.
Corresponding action: R01
0 secs.
0-99
secs.
F.07
Setting time of screen cleaning after suction
Set 0 as no screen cleaning after suction.
Corresponding action: R11
5 secs.
0-99
secs.
F.08
Screen cleaning cycle
It starts once [F.06] or [F.07] cleaning action only after
several times of repeated suction actions.
Set 1 as cleaning the screen cleaning at every suction.
10 times
1-99
times
F.09
Circulating suction waiting time
Waiting time before a new suction action starts after each
suction action.
Set 0 as not waiting.
Waiting time before a new suction action starts
Corresponding action: N03
(Unit
10
secs.)
0-9990
F.10
Shortage metering alarm
Set the number of times that the material doesn’t fall into the
hopper, and it should alarm after several times of this error
occurs.
Alarm cleaning mode:
1.The alarm will dismiss when it feeds the materials again.
2. Ent key on the panel can be cancelled.
3.Turn on the power again.
Set 9 as cancelling this function.
Corresponding action: A.01
3 1-9 times