EasyManua.ls Logo

Shini SAL-430 - Parameter Setting

Shini SAL-430
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18(29)
4.2 Parameter Setting
In OFF modePress , and enter parameter setting.
Press or to select parameterpress enter setting.
Press or modify parameterspress Confirm revision.
E.gsetSuction time setting 15S
In OFF modePress and enter parameter setting.
Press or key to select the function code F.01, and press key
to enter.
Press or key to change it to parameter 15, and press key to
confirm after modification.
Code Status
Parameters
Preset
value
Range
F.01
Suction action time
Motor suction time when theres a shortage of materials,
which is also the vacuum breaking valves working time.
Corresponding action: D
15 secs.
5-127
secs.
F.02
Shut-off action time
Start with the suction action at the same time, and set the
shut-off time. The time cant be set exceed the suction action
time, and set it to 0 as not start.
0
0-127
secs.
F.03
Mixing proportion
Start at the same time with the suction action, and set the
mixing proportion.
Time calculation method: suction time * [F.03]%
Set 0 as not start.
0%
Not start
0-100%

Related product manuals