23(29)
4.6 Communication Address(protocol modbus-RTU)
Address
(keeping
deposit
zone)
(decimal)
Parameters
Reading R/
Writing W
Default
Parameter
Min.
Value
Max.
Value
Unit
0
Current action
R /
/
bit 0 shutdown 0 1
bit 1 standby 0 1
bit 2 absorb materials 0 1
bit 3 wait for material
discharge
0 1
bit 4 cleaning the screen 0 1
bit 5 wait for motor stopping
0 1
bit 6 screen blockage alarm
0 1
bit 7 shortage alarm 0 1
Bit 8~bit 16 undefined
1 Real-time info. R / /
3 Suction action time R/W 15 5 127 S
4
Screen cleaning action
cycle
R/W 10 1 99 次
6
Screen cleaning setting
time
R/W 0 99 S
7 Discharge checking time R/W 10 5 99 S
8
Standby time after motor
running
R/W 0 0 99 S
9
Screen cleaning setting
time
after suction
R/W 5 0 99 S
10
Waiting time for
circulating suction
R/W 0 0 9990 10S
13
Input and output status
R /
/
bit 0 shortage input signal
0 full
mat.
1 mat.
shortage
bit 1 filter screen blockage
input signal
0
no
blockag
e
1
blockage
bit 4 suction output
0 no
output
1 output
bit 5 spraying valve output
0 no
output
1 output
bit 6 alarm output
0 no
output
1 output
bit7~bit15 undefined
14
Current action
R /
/
bit 0 shutdown 0 1