24(29)
bit 1 standby 0 1
bit 2 absorbing materials
0 1
bit 3 waiting for material
discharge
0 1
bit 4 clean the filter screen
0 1
bit 5 wait for motor stop 0 1
bit 6 filter blockage alarm
0 1
bit 7 shortage alarm 0 1
bit8~bit15 undefined
15 Startup & shutdown control
W /
0
startup
1
shutdown
/
16 Suction action time R/W 15 5 127 S
17 Mixing proportion R/W 0 0 100 %
18
Circulating startup setting
of mixing action counting
R/W 1 1 9
time
s
19 Filter screen action cycle R/W 3 1 99
time
s
20
Circulating suction waiting
time
R/W 0 0 9990 10S
21
Screen cleaning setting
time before suction
R/W 0 0 99 S
22
Screen cleaning setting
time after suction
R/W 5 0 99 S
23 Discharge checking time R/W 10 5 99 S
24
Material shortage counting
alarm
R/W 3 1 9
time
s
25
Material shortage counting
stop alarm
R/W 3
Mat.
shortag
e
countin
g alarm
99
time
s
26
Standby time after motor
running
R/W 20 0 99 S
27 Buzzer alarm type R/W 1 0 2 /
29 Motor working time record R/W 0 0 999 10h
30 Full mat. detecting time R/W 3 1 9 S
31
Mat. shortage detecting
time
R/W 3 1 9 S
32 Mat. shut-off time R/W 0 0 100 S
34 Motor delay stop time R/W 0 0 999 S
35
Accumulating times of
mixing actions
R 0 0
0x03
set value
time
s
36
Accumulating times of
screen cleaning actions
R 0 0
0x04 set
value
time
s
37
Accumulating times of
material shortage alarm
R 0 0 99
time
s
38 Startup & shutdown control
W
0
startup
1
shutdown
/
39
Current action
R /
/
bit 0 startup 0 1

Related product manuals