25(29)
bit 1 standby 0 1
bit 2 cleaning the filter
screen
0 1
bit 3 wait for motor stopping
0 1
bit 4 absorb the material
0 1
bit 5 absorb the
masterbatch material
(mixing)
0 1
bit 6 wait for material
discharge
0 1
bit 7 wait for circulating
suction
0 1
Bit 8 ~bit 15 undefined
40 real-time information R / /
41
Input and output state
R /
/
bit 0 shortage input signal
0 full
mat.
1 mat.
shortage
bit 1 filter blockage input
signal
0 no
blockin
g
1
blocking
bit 2 suction output
0 no
output
1 output
bit 3 vacuum breaking
output
0 no
output
1 output
bit 4 mixing output
0 no
output
1 output
bit 5 spraying valve
output
0 no
output
1 output
bit 6 alarm output
0 no
output
1 output
bit7~bit15 undefined
42
alarm state
R /
/
bit 0 shortage alarm 0 1
bit 1 mat. shortage stop
alarm
0 1
bit 2 filter blockage
alarm
0 1
bit 3~bit 15 undefined
45
The number of mixing
layers
R/W 1 1 4 layer
46
Action mode
(only can be set in
shutdown)
R/W 5 1 5 /
Notes:R means only reading
W means only writing
R/W means writing and reading
Note: The password is not set in factory, which can be set by
users. In case of loss, please contact us.