10(65)
1.3 Technical Specifications
1.3.1 Specification
Table 1-1:Specification
Tank(L)
Model
Max.
temp.
(kw)
Pump (kw)
(50/60Hz)
flow (L/min)
(50/60Hz)
Max. pu
pressure
(bar)
(50/60Hz)
Heating
chamber
number
Heat
ing
Cooli
ng
method
Mould
coupling*
(inch)
Inlet /
Outlet
(inch)
Dimensions
(mm)
(H×W×D)
Weight
(kg)
STM-607PW
6 0.55 / 0.63
27 / 30 4.25 / 5.9
1 3.0
0.8
670×320×750
75
STM-1220PW
160℃
12 1.0 / 1.0
50 / 50.8
5.8 / 7.77
1 3.2
0.8
Indirect
3/8 (2×2)
3
/
4
/
3
/
4
670×320×900
80
Note: 1) "PW" stands for high temp. water heater, "HPW" stand for water We reserve the right to change
heater with high temperature and high pressure, "*" stands for specifications without prior notice.
options.
2) To ensure stable water temperature, cooling water pressure should
not be less than 2kgf/cm
2
,but also no more than 5kgf/cm
2
.
3) Pump testing standard: Power of 50 / 60Hz,purified water at 20℃.
( There is ±10% tolerance for either max. flowrate or max. pressure ).
4) Power supply: 3Φ, 230/400/460/575VAC, 50/60Hz.