Shure Incorporated
76/103
◦
◦
◦
◦
◦
◦
◦
◦
◦
◦
Utility Tab
① Export Button
Exports MXW device data to a text file (.csv).
② Configuration Filter
When checked, the table displays data for only the devices that belong to the Configuration or are open for association. Un-
check the filter to view all MXW devices on the subnet.
Note: The filter is checked when the configuration is locked from the Configuration tab.
③ Group
Indicates the device's status in a Group:
1 - 10: Device is associated to that Group in the Configuration
Open: Device is not associated to any group
None: Microphone is linked to an Access Point that has been removed from a group (deselected from the Group row in the
Configuration tab)
Standalone: Audio Network Interface is set to Standalone mode, which restricts association to an APT group
Unknown: Microphone is linked to an APT that is powered off or connected to a different network
Other: Device is associated to a Group in a different Configuration
④ Device
The device type or microphone channel.
APT: Access point transceiver; also displays the selected channel density mode (SD = standard, HD = high)
NCS: Network charging station, up to two per group (A or B)
Mic 1 - 8: Microphone for channels 1-8, up to two microphones per channel (primary or secondary)
Out: Device is not associated or linked to a group
⑤ Type