EasyManua.ls Logo

SICK deTec4 C4C-EV03030A10000

SICK deTec4 C4C-EV03030A10000
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.4.3 Connection diagrams
Connection diagram for RLY3-OSSD2 with restart interlock and external device moni‐
t
oring
1
2
4
3
5
2) PELV
r
System connection
+24 V DC
OSSD1
OSSD2
0 V
n.c.
1
2
4
3
5
s
System connection
+24 V DC
n.c.
n.c.
0 V
n.c.
F2 F1
+24 V DC
0 V DC
K1K2
E243749/02/2020-07-10
R1 Y1 Y2 24A2 14
S
1 I1 I2 23A1 13
RLY3-OSSD2
k2
z
k1 k2
k1
z
x
y
x
1)
y
F0
L+
L–
deTec2 Core
deT
ec4 Core
k2
k1
S1
Figure 19: Connection diagram for RLY3-OSSD2 with restart interlock and external device moni‐
t
oring
1) Output circuits: These contacts must be incorporated into the control such that the
dangerous state is brought to an end if the output circuit is open. For categories 4 and 3,
they must be incorporated on dual-channels (x, y paths). Type 2 devices are suitable for
use up to PL c. Single-channel incorporation into the control (z path) is only possible with
a single-channel control and taking the risk analysis into account.
2) SELV/PELV safety extra-low voltage.
T
ask
Connection of a deTec4 Core Vibes safety light curtain to a RLY3-OSSD2 safety
r
elay. Operating mode: With restart interlock and external device monitoring.
Mode of opera
tion
When the protective field is clear, the OSSD 1 and OSSD 2 outputs carry voltage.
T
he system can be switched on when K1 and K2 are in a fault-free de-energized
position. The RLY3-OSSD2 is switched on by pressing S1 (pushbutton is pressed
and released). The outputs (contacts 13-14 and 23-24) switch the K1 and K2
contactors on. When the protective field is interrupted, the OSSD 1 and OSSD 2
outputs switch the RLY3-OSSD2 off. Contactors K1 and K2 are switched off.
F
ault analysis
Cross-circuits and short-circuits of the OSSDs are recognized and lead to the
loc
king status (lock-out). A malfunction with one of the K1 or K2 contactors is
detected. The switch-off function is retained. In the event of manipulation (e.g.,
jamming) of the S1 pushbutton, the RLY3-OSSD2 will not re-enable the output
current circuits.
4.5 Testing plan
The manufacturer of the machine and the operating entity must define all required
c
hecks. The definition must be based on the application conditions and the risk assess‐
ment and must be documented in a traceable manner.
PROJECT PLANNING 4
8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes
27
Subject to change without notice

Table of Contents

Related product manuals