Minimum Typical Maximum
Housing cross-section 31 mm × 34 mm, plus bracket, see "Dimensional dr
aw‐
ings", page 58
Vibration resistance
4)
10 Hz … 200 Hz: 20 g in each axis
200 Hz … 400 Hz: 15 g in each axis
Shock resistance
1))
10 g, 16 ms (IEC 60068-2-27)
1)
maximum permissible conductor resistance must be observed.
1))
The temperature difference between sender and receiver must not exceed 25 K.
2)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25 °C
.
3)
In addition to the swept-sine tests described in accordance with IEC 60068-2-6, the safety light curtain
was subjected to additional tests. The tested devices passed tests with a frequency sensing range
between 200 Hz and 2 kHz (broadband noise) and an acceleration of 10 g over 8 h in each axis without
any modifications.
4)
In addition to tests in accordance with IEC 60068-2-27, the safety light curtain was subjected to addi‐
t
ional continuous shock tests. The tested devices passed tests with 1,000,000 shocks and an accelera‐
tion of 30 g as well as tests with 100,000 shocks and an acceleration of 100 g without any modifica‐
tions.
12.2 Response time
Table 12: Response time dependent on the protective field height
Protective field height in mm Response time in ms
300 10
450 10
600 10
750 11
900 11
1050 11
1200 12
1350 12
1500 13
1650 13
1800 13
1950 14
2100 14
12.3 Power consumption
Table 13: Power consumption, sender and receiver
Protective field height in mm Typical power consumption for
sender in W
Typical power consumption for
r
eceiver in W
1)
Resolution 30 mm Resolution 30 mm
300 0.82 1.63
450 0.86 1.73
600 0.91 1.82
750 0.96 1.92
900 1.01 2.02
1050 1.06 2.11
1200 1.10 2.21
1350 1.15 2.30
12 TECHNICAL DATA
56
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/2019-06-18 | SICK
Subject to change without notice