Using reversed direction of transmission
T
he direction of transmission of the system 2 can be changed during installation by
switching the positions of the sender and receiver. With reversed direction of transmis‐
sion, the receiver 2 is not affected by the infrared light from the sender 1.
"
!
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
rs
r
Figure 15: Trouble-free operation due to reversed direction of transmission of system
1
and sys‐
tem
2
Further topics
"Connection of sender and receiver", page 36
"Combining beam coding and reversed direction of transmission", page 31
4.3.4.3 Combining beam coding and reversed direction of transmission
To prevent a mutual interference in the case of more than two neighboring systems,
be
am coding and reversed direction of transmission can be combined.
s r
Code 1
s r
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
r
r
r
r
r
s
r
r
r
r
r
s
rs
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
rs
Code 2
Code 2Code 1
Figure 16: Trouble-free operation of 4 neighboring systems due to beam coding and reversed
dir
ection of transmission
In the figure, the beam coding of the systems arranged next to each other is different.
The direction of transmission of the systems arranged on top of each other is reversed.
This prevents the systems from interfering with each other.
4.4 Integration in electrical control
Overview
T
his chapter contains important information about integration in the electrical control.
Information about the individual steps for electrical installation of the device: see "Elec‐
trical installation", page 56.
PROJECT PLANNING 4