Minimum Typical Maximum
Shock resistance
5)
10 g, 16 ms (IEC 60068-2-27)
1)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25 °C
.
1))
The temperature difference between sender and receiver must not exceed 25 K.
2)
Maximum ambient operating temperature over 1,000 m above NHN: +50 °C.
Maximum ambient operating temperature over 2,000 m above sea level: +45 °C.
3)
Test conditions per axis: 1 octave/minute, amplitude: 0.35 mm, 20 sweeps.
4)
Test conditions per axis: 1,000 shocks.
5)
maximum permissible conductor resistance must be observed.
13.2 Response time
Table 26: Response time for a single device
Protective field height in mm Response time in ms
Uncoded Code 1 or code 2
450 10 14
600 10 15
900 11 17
1200 12 20
1500 13 22
13.3 Power consumption
Table 27: Power consumption for sender and receiver, 30 mm resolution
Protective field height in mm Typical power consumption
f
or sender in W
Typical power consumption
for receiver in W
1)
2)
450 1.31 3.30
600 1.38 3.36
900 1.53 3.50
1200 1.68 3.63
1500 1.82 3.76
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
t
able values.
2)
The power consumption increases by 0.5 W with the use of a receiver with integrated LED.
13.4 Table of weights
Table 28: Weight of sender and receiver
Protective field height in mm Weight in kg
1)
s Sender r Receiver
450 30.13 30.14
600 29.35 29.36
900 37.7 37.71
1200 46.05 46.06
1500 46.32 46.33
1)
Tolerance: ± 50 g.