Minimum Typical Maximum
Discrepancy time (time offset
be
tween switching of OSSD2 and
OSSD1)
1 ms
Inputs
Input voltage HIGH (active)
2)
11 V 24 V 30 V
Input current HIGH 6 mA 10 mA 20 mA
Input voltage LOW (deactivated)
2)
0 V 5 V
Input current LOW -2.5 mA 0 mA 0.5 mA
External device monitoring input (EDM)
Connected contactors
Permissible dropout time 300 ms
Permissible pull in time 300 ms
Reset pushbutton input (RES)
Control switch actuation time 50 ms
Application diagnostic output (ADO)
PNP semiconductor, short-circuit protected
1)
Output voltage HIGH (active) U
V
- 3 V
Output voltage LOW (inactive) High resistance
Output current HIGH (active) 100 mA
Permissible conductor resistance
5)
Supply cable
6)
1 Ω
Cable between OSSD and load 2.5 Ω
1)
Applies to the voltage range between -30 V and +30 V.
2)
According to IEC 61131-2.
3)
The specified values are the switching voltage passed to the safety light curtain. If higher voltages are
im
pressed from the outside, the maximum value of 2.0 V can be exceeded.
4)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers,
make sure that the test signals do not result in deactivation when using the above parameters.
5)
Limit the individual conductor resistance to the specified values to ensure that the light curtain functions
correctly, particularly that a cross-circuit between the outputs is safely detected. (Also observe
IEC 60204-1.)
The specified values apply to the total resistance of each conductor including contact and connector
resistances.
6)
The supply cable must not be used to connect other loads with the exception of the senders.
Table 25: Operating data
Minimum Typical Maximum
System connection Flying leads, 8-wire, 30 m preassembled
Ambient operating temperature
1))
2)
3)
–20 °C +55 °C
Air humidity (non-condensing) 15% 95%
Storage temperature -30 °C +70 °C
Housing cross-section 142 mm × 163 mm, plus bracket, see "Dimensional
dr
awings", page 93
Vibration resistance
4)
5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
TECHNICAL DATA 13
8022883/2019-03-07 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex
91
Subject to change without notice