Complementary information
In man
y cases, the optional AR60 laser alignment aid and the alignment tool available
as an accessory can make alignment even easier. If deflector mirrors are installed, the
laser alignment aid can be used at the receiver. If there is a large protective field height,
it can be used at the top end of the sender and at the receiver.
Since the optional AR60 laser alignment aid is placed with the adapter inside the pro‐
tective field of the safety light curtain, at most diagnostic LEDs 1 and 2 light up blue
and the OSSD LED lights up red. To check whether the OSSD LED of the receiver lights
up green and diagnostic LEDs 5,6,7 and 8 light up blue, remove the optional AR60
laser alignment aid.
Further topics
•
"Indic
ation of the alignment quality", page 71
•
"Mounting", page 43
•
"Accessories", page 99
•
"Laser alignment aid", page 37
8.4.2 Alignment with the alignment bracket
The alignment bracket offers you the following adjustment options for aligning the
sender and r
eceiver with each other:
•
Rotate (± 45°)
Figure 48: Alignment bracket: rotate
8 C
OMMISSIONING
70
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex 8022883/2019-03-07 | SICK
Subject to change without notice