LEDs Meaning
Diagnostics LEDs
1 2 3 4 5 6 7 8
O
Blue
O
Blue
The bottommost light beam (near
s
ystem plug) is synchronized.
o LED of
f. Ö LED flashes. O LED illuminates.
1)
If external device monitoring is configured and there is an EDM warning, diagnostic LED 1 flashes, while
the other diagnostic LEDs 2, 3 and 4 indicate the alignment quality. If there is an error on the reset push‐
button, diagnostic LED 4 flashes, while the other diagnostic LEDs 1, 2 and 3 indicate the alignment qual‐
ity.
2)
If the protective fields are very wide, there is a possibility that diagnostic LED 4 does not light up, even
with optimal alignment.
Further topics
"Indic
ations when switching on", page 79
8.5 Check during commissioning and modifications
The check must detect if it is possible to enter the hazardous area without being
de
tected.
b
C
arry out the checks according to the instructions from the manufacturer of the
machine and from the operating entity.
8 C
OMMISSIONING
72
O P E R A T I N G I N S T R U C T I O N S | deTec4 Ex 8022883/2019-03-07 | SICK
Subject to change without notice

Table of Contents