3.5 Serial Interface Control
3.5.1 Suffix, Preamble, Postamble
PROGRAM
F_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
STX/ ETX Control
SS Disable STX/ETX transmission 0
SS Enable STX/ETX transmission 1
STX/ETX are two characters used to indicate the starting and
ending of the total data frame transmitted via serial
interface.
Record Suffix
SS None 0
SS CR (0DH) 1
SS LF (0AH) 2
SS CRLF (0D0AH) 3
SS TAB (09H) 4
SS SPACE (20H) 5
Preamble
SS None FIN
MS 1-15 characters [00-7F], FIN
Maximum 15-character input; scan “FIN” to terminate this
selection.
Postamble
SS None FIN
MS 1-15 characters [00-7F], FIN
Maximum 15-character input; scan “FIN” to terminate this
selection.
FNC1 Symbol Char.
Transmit
SS Disable 0
SS Enable 1
When this function is enabled and the FNC1 is contained in
scanned data, the scanner transmits the FNC1 to the host. A
chart of the FNC1 is provided in the Appendix Keyboard
Function Code Table. When the scanner interface is set to
keyboard, the scanned code is converted to corresponding
key function before it is transmitted.
Serial Interface Message String (RS-232, USB COM)
STX Preamble
Data
Length
Prefix
Symbol ID
Scanned
Data
Suffix
Symbol ID
Postamble ETX
Record
Suffix
1
character
1-15
characters
2-4
digits
1 or 3
characters
Variable
length
1 or 3
characters
1-15
characters
1
character
1
character

Table of Contents