8016441/2013-11-22•©SICKAG•Subjecttochangewithoutnotice 37
Operating the device
"Menu" menu continued
Parameter Description
MF2Out EthLnk
Activatesordeactivatesthewarningmessagewhenthereisno
Ethernetcableconnected.
Options
•On
•Off
Factory setting
•Off
WrnLvl
Activatesordeactivatesthewarningmessagewhentherecei-
vedsignalleveldrops,e.g.duetocontamination.
Options
•On
•Off
Factory setting
•Off
NotRdy:
Activatesordeactivatesthewarningmessagewhenthelaser
isnotreadyforoperation.Thismaybeduetoahardwareerror
oritmaybebecausethelaserisswitchedoff.Thiswarning
messageisalsoissuedduringinitialization.
Options
•On
•Off
Factory setting
•On
Heat
Activatesordeactivatesthewarningmessagewhenthe
heatingisswitchedon.Thisparameterisonlydisplayedon
deviceswiththe"Heating"option(ISD400-7X2X)
Options
•On
•Off
Factory setting
•Off
Heat •Thisparameterisonlydisplayedondeviceswiththe"Hea-
ting"option(ISD400-7X2X)
•Denestheswitch-onthresholdfortheheating(–10to
+40°C).
Factory setting
•–10°C
Reset Resetsallparametersinthemenu.
Table 9: "Menu" menu