Operating the device
38 ©SICKAG•Subjecttochangewithoutnotice•8016441/2013-11-22
"Count" menu The"Count"menudisplaysallcountsfortheswitchingeventsinTable10
(page38).Youcanresetthecounterbyswitchingthedeviceoffandon
again.
The"Count"menuisaccessedviathefollowingmenupath:
Operatingmode→
→Menu→ →Count
Pressthe
pushbuttontodisplaythe"OptBrk"parameter.
Parameter Description
OptBrk Numberoflightpathinterruptions
WrnTmp Numberoftemperaturewarnings
EthLink NumberofEthernetlinkinterruptions
Reset Yes:Resetsallcountersinthe"Count"menu.
Table 10: "Count" menu
NOTE
If a value or a piece of information in menu mode
consists of more than six characters, the characters are
automatically shown successively in the display.
"SwVers" menu The"SwVers"menudisplaysallinformationrelatingtothesoftware.
The"SwVers"menuisaccessedviathefollowingmenupath:
Operatingmode→
→Menu→ →SwVers
Pressthe
pushbuttontodisplaythe"SwVers"parameter.
Parameter Description
SwVers Displaystheversionnumber
Table 11: "SwVers" menu
NOTE
If a value or a piece of information in menu mode
consists of more than six characters, the characters are
automatically shown successively in the display.
"HwVers" menu The"HwVers"menudisplaysallinformationrelatingtothehardware.
The"HwVers"menuisaccessedviathefollowingmenupath:
Operatingmode→
→Menu→ →HwVers
Pressthe
pushbuttontodisplaythe"HwVers"parameter.
Parameter Description
HwVers Displaystheversionnumber
Table 12: "HwVers" menu