8014640/YWI5/2016-08-08 • Subject to change without notice • SICK AG • Waldkirch • Germany • www.sick.com 8LECTOR62X | SICK
8014640/YWI5/2016-08-08 • 8M_AK/ITL (2016-08) • Printed in Germany • All rights reserved • Subject to change without notice
Pin assignment overview
Power / SerialData / CAN / IO Ethernet
Not valid for ECO variant ECO variant Not for ECO variant
1
7
2
6
5
4
13
17
9
1
17-pin M12 male connector, A-coded 15-pin D-Sub-HD male connector on
cable, e.g. no. 2055419 (2 m)
4-pin M12 female connector, D-coded
Pin Signal Signal Signal
1 GND DC 10 V … 30 V TX+
2 DC 10 V … 30 V RxD (RS-232), Aux RX+
3 CAN L TxD (RS-232), Aux TX–
4 CAN H Sensor 2 RX–
5 TD+ (RS-422), Host GND –
6 TD– (RS-422), Host
TxD (RS-232), Host
RD+ (RS-422), Host –
7 TxD (RS-232), Aux RD– (RS-422), Host
RxD (RS-232), Host
–
8 RxD (RS-232), Aux TD+ (RS-422), Host –
9 SensGND TD– (RS-422), Host
TxD (RS-232), Host
–
10 Sensor 1, switching input CAN H –
11 RD+ (RS-422), Host CAN L –
12 RD– (RS-422), Host
RxD (RS-232), Host
Result 1, switching output –
13 Result 1, switching output Result 2, switching output –
14 Result 2, switching output Sensor 1, switching input –
15 Sensor 2 switching input SensGND –
16 Result 3 switching output – –
17 Result 4 switching output – –