EasyManua.ls Logo

SICK PAC50 - Page 73

SICK PAC50
130 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions | SICK 73
Operating Instructions PAC50
8017612/ZAB1/2017-02-14 | PAC50
Subject to change without notice
7 Operation and parameter settings
Description Value range Factory settings
DISC PARA
Indicator color on the display:
Red when p < SP and/or FL < p < FH, and green when p > SP and/
or p < FL, or p > FH: OD
Red when p > SP and/or p < FL or p > FH, and green when p < SP
and/or FL < p < FH: DU
Always red (no color change): RED
Always green (no color change): GRN
Display OFF (energy-saving mode: the display is activated for
10 seconds by pressing one of the pushbuttons): OFF
OD, DU, RED, GRN, OFF OD
HIGH Value Displays the maximum pressure value applied No possibility of setting LLR
LOW Value Displays the minimum pressure value applied No possibility of setting ULR
RHL YES/NO Resets the HIGH and LOW values
PAS Value
Sets the password for the display lock
Password = "0000" = no password entry required
none
TAG Value
END 16-digit alphanumeric measuring point number
none
Display mode
LLR: Lower limit of measuring range
ULR: Upper limit of measuring range
EF: Extended programming functions

Related product manuals