NOTE
Pre-assembled cables can be found online at:
•
www.sick.com/RFU61x
Pre-assembled cables with open cable end at one end
NOTE
For information on the pin, signal and wire color assignments for the RFU61x see "Sig‐
nal assignment of cables with open cable end at one end", page 65, in the appendix.
6.3 Overview of all interfaces and connection options
NOTE
The USB interface of the device is used in industrial environments only as a service
interface for temporary use (e.g. for configuration, troubleshooting). Permanent use in
operational use of the system as a host interface is not intended.
NOTE
The numbering of the data interfaces (Aux 1, etc.) in the following block diagrams pro‐
vides a better overview, but is not shown in configuration tools such as the SOPAS ET
configuration software.
6.3.1 RFU61x-106xx (connection: power and Ethernet)
Service operation
The following functions can be executed via one of the three data interfaces (Aux 1, Aux
2 or Host 1):
•
Configuration
•
Representation of the reading result (detected transponders)
•
Transponder access (reading and writing data)
•
Reading diagnostics (read result in fixed output format)
For a detailed overview, see "Use of the data interfaces", page 38.
This is illustrated here for the Aux interface, the Aux port of the Ethernet interface, and
alternatively the USB interface.
SOPAS ETSOPAS ET
PC
"Ethernet (Aux 1)"
USBUSB
RFU61x-
106xx
Cable 3
Cable 2
5
Power"
EthernetEthernet
"USB" (Aux 2), for temporary use only 4
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
Ready
RF
Link/Act
microSD
Cable 6
V
S
1
Figure 12: Block diagram RFU61x-106xx (power and Ethernet connection): service operation, e.g.
display of read result
1
Supply voltage V
S
2
Power adapter cable for connection 1 (female connector, M12, 4-pin, A-coded/flying
leads), e.g. part no. 2095607
3
USB adapter cable (male connector, USB, Micro-B type/male connector, USB, type A)
ELECTRICAL INSTALLATION 6
8024536//2019-08-30 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU61x
35