14 Annex
14.1 EU declaration of conformity / Certificates
The EU declaration of conformity and other certificates can be downloaded from the
Internet at:
www.sick.com/RFU61x
14.2 Certification according to UL61010-1
Several devices in the RFU6xx product family are certified to UL 61010-1; the UL file
number is E336916.
The certification is only valid for specific type descriptions on the type label of the
respective device, see "Type label", page 13.
Device type RFU61x: see "Features", page 61
UL-certified devices require a supply voltage according to ES1, EN 62368-1, NEC protec‐
tion class 2 (UL13010).
The IP67 enclosure rating of the device is not checked by UL.
14.3 Signal assignment of cables with open cable end at one end
14.3.1 “Power” connection to customer-specific connection equipment or control cabinet
Adapter cable
Part no. 2095607 (2 m), part no. 2095608 (5 m), part no. 2095609 (10 m), female
connector, straight, M12, 4-wire, A-coded, unshielded, suitable for drag chain, deep-
freeze compatible
For RFU61x, “Power” connection (male connector, M12, 4-pin, A-coded)
Ambient temperature range:
For mobile installation: –25 °C to +80 °C, for fixed installation: –40 °C to +80 °C
2
ð
1
43
5
2
1
Figure 27: Adapter cable, part no. 2095607 (2 m), part no. 2095608 (5 m), part no. 2095609
(10 m) with one flying lead
1
Female connector, straight, M12, 5-pin, A-coded (view from front)
2
Illustration may differ
Table 23: Signal assignment of adapter cable with open end
Pin Signal Function Wire color
1 V
S
Supply voltage Brown
2 Reserved (Do not use.) White
3 GND_ext Primary ground Blue
4 Reserved (Do not use.) Black
ANNEX 14
8024536//2019-08-30 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU61x
65
Subject to change without notice

Table of Contents