Switching behavior Power to the input starts the assigned function, e.g. start of the
internal reading interval of the device. Default: active high,
debounce time: 10 ms (standard)
Features
Can be wired with PNP output of a trigger sensor
Electrical values Low: V
in
1)
≤ 2 V; I
in
2)
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 32 V; 0.7 mA ≤ I
in
≤ 5 mA
1)
Input voltage.
2)
Input current.
6.9 Wiring the data interface
Wiring the Internet interface
1. Connect the device to the Ethernet interface of the PC via an adapter cable.
2. Set up communication via SOPAS ET configuration software.
NOTE
The Ethernet interface of the device has an Auto-MDIX function. This automatically
adjusts the transmission speed as well as any necessary crossover connections.