12 Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
www.sick.com/RFU61x
These operating instructions provides additional technical data if required.
12.1
Features
Table 19: Technical data for RFU61x: Features
RFU61x-106xx
Version
(working range)
Short range
Product category RFID read/write device (UHF) with integrated antenna
Frequency band UHF (860 MHz ... 960 MHz)
Radio equipment approval
(regional assignment)
Depending on type.
See type-specific online data sheet at: www.sick.com/RFU61x
Carrier frequency
Transmission output power
RFID standard (air inter‐
face)
EPCglobal UHF Class 1 Generation 2, ISO/IEC 18000-6 C
Labeling in type code: RFU6x0-xxxxx
Modulation PR-ASK
Connection type Power and Ethernet or PoE
Sensing range Typically: 0.5 m
1)
Antenna Integrated antenna
•
Transmitting power: adjustable
•
Polarization: circular (LHCP)
•
Axis behavior: typically 2 dB (ETSI), 3 dB (FCC)
•
Aperture angle: 110°
•
Front-to-back ratio: typically > 5 dB
Service functions Semi-automated saving of parameter data (parameter cloning)
outside the device memory:
•
Using insertable microSD memory card
2)
in the device
Clock Network time protocol (NTP), no internal clock
Conformities Depending on type. See type-specific online data sheet at:
www.sick.com/RFU61x
Certificates Depending on type. See “Downloads” section online at:
www.sick.com/RFU61x
1)
Sensing range depends on the transponder used and the ambient conditions.
2)
Optional accessories.
3)
UL-certified if the type label contains the UL logo and the UL conditions are met during device operation.
For further information, see "Certification according to UL61010-1", page 65.
TECHNICAL DATA 12
8024536//2019-08-30 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU61x
61
Subject to change without notice