NOTE
UL-certified devices (see type label) require a supply voltage according to ES1, EN
62368-1, NEC protection class 2 (UL13010).
The power source must be able to provide the following power outputs when the device
is operating at maximum transmitting power:
Table 11: RFU61x: required supply voltage V
S
Device Supply voltage V
S
Ambient operating
temperature
Power source:
required power output
RFU61x-106xx DC 18 V ... 30 V -25 °C ... +50 °C At least 6 W
DC 48 V / 57 V according
to PoE technology
Power supply options
The device offers two voltage supply options:
1. Power and Ethernet: DC 18 V ... 30 V
°
Connection 1: power
°
Connection 2: Ethernet
2. Power over Ethernet (PoE): DC 48 V / 57 V according to PoE technology
°
Connection 1: not assigned
°
Connection 2: PoE
It is possible to use both variants at the same time. However, it is recommended to
select just one variant.
Table 12: Using connection variants at the same time: behavior of the device
Initial situation Change Effect
Voltage supply power via con‐
nection 1
Additionally, PoE connected to
connection 2.
No effect on the device status.
Voltage supply PoE via connec‐
tion 2
Additionally, power connected
to connection 1.
No effect on the device status.
Voltage supply with immediate
effect via power to connection
1 (dominant).
Voltage supply power via con‐
nection 1 (dominant) and PoE
via connection 2
Connecting power to connec‐
tion 1 is isolated.
Device restarts.
Voltage supply with immediate
effect via PoE to connection 2.
NOTE
The voltage supply via a power supply unit must be capable of buffering a brief power
failure of 20 ms.
Protecting the supply cables
To ensure protection against short-circuits and overload in the customer-supplied
cables, the wire cross-sections used must be selected and protected in accordance
with national regulations.
The following standards must be observed in Germany:
•
DIN VDE 0100 (part 430)
•
DIN VDE 0298 (part 4) and/or DIN VDE 0891 (part 1)
When the device is supplied via the “Power” connection, fuse the supply voltage DC
18 V to 30 V with a separate 0.8 A slow-blow fuse.
b
Install the fuse in the supply circuit at the start of the supply cable.
6 ELECTRICAL INSTALLATION
44
O P E R A T I N G I N S T R U C T I O N S | RFU61x 8024536//2019-08-30 | SICK
Subject to change without notice